WIEGHT
MEASURING
LOAD CELL
MV-150

Download pdf
russian | english
 |   |   | 


DIMENSIONS

Capacity, t 20, 30, 40, 60 100
Н, mm 150 178
D1, mm 44 62
D2, mm 75 101

SPECIFICATION

Parameter Unit Value
Capacity (Emax) t 20; 30; 40; 60
Accuracy class according to OIML R60 (GOST 30129-96) С1 С3
Quantity of verification interval 1000 3000
Minimum verification interval Emax/5000 Emax/10000
Rated output (Cn) mV / V 2 ±0.004 2 ±0.002
Dead load output % Cn ±2 ±2
Combined error % Cn ±0.030 ±0.020
Creep error (30 min.) % Cn ±0.049 ±0.025
Temperature effect on minimum dead load output % Cn / °C ±0.0028 ±0.0014
Temperature effect on rated output % Cn / °C ±0.0022 ±0.0011
Maximum excitation voltage V 12
Input resistance 1150 ± 50
Output resistance 1000 ±2
Insulation resistance M > 5000
Compensated temperature range °C -10...+40
Operating temperature range °C -50...+50
Storing temperature range °C -50...+60
Степень защиты по ГОСТ 14254-96 IP68
Safe overload (1 hour) % Emax 25
Ultimate load % Emax 300
Load cell material Stainless steel
Protection rate IP68
Weight kg 3,7
Cable lenght m 16


General information  |  Features  |  Specification  |  Force apllying devices